Protect the water course from fuel and chemical spillages on filling station forecourts
Class 1 Discharge Separators connect to a surface drain
Class 2 Discharge Separators connect to a foul drain
Full flow treatment of rain falling at a rate of up to 50mm per hour.
The standard range covers Class 1 Discharge and Class 2 Discharge specifications to NS100.
Larger models are are available.
Automatic closure and pollutant level monitor are usually required.
With water authority agreement, a coalescing filter may not be needed if discharging into a foul sewer.
The above requires manhole cover(s) and lid(s) (not included). Due to the weights involved covers and lids are expensive to transport and often cost more to ship than they are worth so we advise you source your own. You can purchase covers and lids from most builders merchants and below is a guide to assist you choosing the best type for the duty.


| Type | Size (mm) | Duty | European Standard | Loading | Typical Overground |
|---|---|---|---|---|---|
| Class A15 | 600 x 450 | Light | BS EN 124 | 3 tonne (approx) | Cars/Small Vans |
| Class B125 | Medium | 17 tonne (approx) | Cars/Small Commercial | ||
| Class D400 | Heavy | 38 tonne (approx) | Large Commercials/HGV |
EA and SEPA Pollution Prevention Guidelines (PPG)
The EA and SEPA Pollution Prevention Guidelines (PPG) which are jointly produced by the Environment Agency for England and Wales, the Scottish Environment Protection Agency, and the Environment and Heritage Service for Northern Ireland (Ref PPG3 / PPG13 / PPG4 / PPG 14) suggest that Class 2 wash bay silt traps and interceptors should be connected only to a mains foul drain, and Class 1 separators to surface drain.
The above assumes you have the consent to connect any outflow to a suitable drain as per the appropriate PPG Guideline. While we always endeavour to provide best advice and accurate information, it the responsibility of the client and/or landowner to comply with the law. Following any guideline doesn’t remove your responsibility to comply with the law and prevent pollution from your activities. Causing or allowing pollution is a criminal offence; compliance with any guidance isn’t a defence. You should make sure that the references to other sources of guidance are still current.
Extract from the Pollution Prevention Guidelines: PPG3
Forecourt separators
This page uses the term forecourt to refer to all forms of liquid-fuel dispensing outlets, both retail and non-retail, including those where only diesel is dispensed.
A forecourt separator must be a 'full retention' separator, large enough to serve the catchment area of the site and have a sufficient oil storage volume to retain any foreseeable spillages.
It is important to install a forecourt separator of an appropriate size. On a forecourt where tanker deliveries are received, a separator with an oil storage capacity of 7,600 litres will meet the requirements of BS EN 858-2, clause 4.3.6.
If a smaller unit is proposed, the size should be determined by undertaking a risk assessment incorporating catchment size, potential spillages during delivery, and other risks such as safety issues. If the compartment size of the tanker that delivers to your site is greater that 7,600 litres your separator should be sized accordingly.
| [ Morclean Home Page | Special Offers | Latest News | Contact Us ] | |||||
|
|
Freephone 0800 1300 402 For export enquiries: export@morclean.com If you have any comments about this site contact office@morclean.com |
Morclean (West Midlands) |
|
||
![]() Morclean is an ISO 9001 registered firm and our quality administration systems have been assured and approved to the standards and guidelines of BS EN ISO 9000:2000 for the sales, service and hire of industrial cleaning equipment. Our registration no. is 94/121120 and our standards and guidelines are externally audited by CIS. Please note that many models described on this website are bespoke, and as such cannot always be accurately depicted. All photographs and illustrations displayed on this website are representative of model ranges or a model series only. Individual models and specifications may vary from those shown. Please contact us if you require clarification or individual specifications of any equipment. Morclean reserve the right to update and amend the specification of our equipment and accessories without notice and in the interest of the customer. Images or specifications must not be reproduced with express written consent from Morclean Ltd. Any prices quoted are subject to VAT @ SR. E&OE Registered in England No. 4605133 |
|||||